The A rated extension and alteration of the semi-detached 3 bed house
is now completed
The A rated extension and alteration of the semi-detached 3 bed house
is now completed
This is a timber frame house extension and a full alteration to the house with external wall insulation.
a permanent a demand control ventilation system was installed for a permanent good air quality, no dampness on bathroom wall and ceiling,
no maintenance cost.
Air tigtness was improved with membrane and taping.
New high condensing gas boiler and solar thermal hot water system.
The house was D1 and is now A3
We, successfully completed a course on thermal bridge calculation with THERM software,
Another step for our design services, we are now in a position to check the performance of our construction details,
for Part L compliance or passive house standard.
Block work at Wall plate level
Open-Web Floor Joist to run services.
Wide wall cavity 300mm, with thermal brake wall tides.
Air tightness flapping membrane section ready at floor level.
For More more info on passive house construction details, please contact us.
good progress are made on the passive house, the plaster work is starting…
This is a A rated house build with some of the Passive house guidelines, 70 % of the work progress completed.
The building technique is insulated concrete form block, this is fast to build, great wall u values and airtighness.
The windows alu clad are triple glazed, the roof is made with prefab insulated panel.
The client is targeting the zero Co2 emission, with the future installation of solar pv panel and heat pump.
For more info contact us.
Loic Dehaye is now officially Passive House Designer
after successfully passed the certified Passive House Examination
from Passivhaus Institut Dr. Wolfgang Feist. Darmstadt, Germany.
This is a great new step to our architect services expertise and certainly new business opportunities.
Champagne !!!!
We have currently a passive house on site using passive house foundation system,
The great benefit of the system makes the foundation thermal bridge free and use less concrete than a traditional build.
It is composed with 3 no layer of 100 mm EPS insulation.
For more info Contact us.
Detail of Heat air recovery ventilation piping system running with in the insulation layer of the ground floor with floor grid outlet .
That is it
The client moved back in, just about unpacking…
We Could not resist to put up some pictures of the back elevation
with a morning sun light
We have currently a one off passive house going on site.
The cost per sqm excluding kitchen and floor finish is +_ € 1000.00/ sqm incl VAT,
house Area is 230.00 sqm, Two storey dormer bungalow type
Who said passive house design is expensive !!!
for more info contact us